EasyManuals Logo

Honeywell HF680 Series User Manual

Honeywell HF680 Series
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
HF680 Series User Guide 63
If the barcode has characters that the host application does not want included, you
can use the E4 command to replace those characters with something else. In this
example, you will replace the zeroes in the barcode above with carriage returns.
Command string: E402300DF10D
E4 is the “Replace characters” command
02 is the total count of characters to be replaced, plus the replacement characters
(0 is replaced by CR, so total characters = 2)
30 is the hex value for 0
0D is the hex value for a CR (the character that will replace the 0)
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
1234
5678
ABC
<CR>
Stop replacing characters
E5 Terminates character replacement. Syntax = E5.
Compare characters
FE Compare the character in the current cursor position to the character “xx.” If
characters are equal, move the cursor forward one position. Syntax = FExx where xx
stands for the comparison character’s hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 164 for
decimal, hex and character codes.
Check for a number
EC Check to make sure there is an ASCII number at the current cursor position. The
format is aborted if the character is not numeric.
EC Example: Only output the data if the barcode begins with a number
If you want only data from barcodes that begin with a number, you can use EC to
check for the number.
Command string: ECF10D
EC is the “Check for a number” command
F1 is the “Send all characters” command
0D is the hex value for a CR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HF680 Series and is the answer not in the manual?

Honeywell HF680 Series Specifications

General IconGeneral
Image SensorCMOS
Symbol Contrast20% minimum reflectance difference
InterfaceUSB, RS-232, Keyboard Wedge
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% (non-condensing)
Light Levels0 to 100, 000 lux
Supported BarcodesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix