Xenon/Granit User Guide 109
number of attempts is reached, the scanner will not attempt to reconnect to a base.
Pressing the trigger or placing the scanner in the base resets the counter and the
scanner will again try to link.
Scan the Maximum Link Attempts bar code, then scan the number of attempts for
the setting (from 0-100) from theProgramming Chart, beginning on page 353,
then Save. Default = 4.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause
the scanner to try to link until the Power Time-Out Timer setting expires. When Auto
Reconnect Mode is Off, setting Maximum Link Attempts to zero will cause the
scanner to only attempt linking one time after a trigger pull.
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts. An attempt to link
a scanner to a base typically lasts up to 5 seconds. This is the time when the scan-
ner is actually attempting a contact. Relink Time-Out controls the amount of time,
in seconds, that elapses between the end of one connection attempt and the start
of the next.
Scan the Relink Time-Out bar code, then scan the number of seconds for the set-
ting (from 1-100) from the Programming Chart, beginning on page 353, then
Save. Default = 2 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to connect
to the base. Each attempt consists of approximately 5 seconds of active time fol-
lowed by 3 seconds of idle time. After one hour, the scanner powers off and batch
mode data is lost.
Example: Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, 15 attempts are made to link to the base.
Each attempt consists of approximately 5 seconds of active time followed by 3 sec-
onds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the scanner
Maximum Link Attempts
Relink Time-Out

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete

Related product manuals