CHAPTER
11
Xenon/Granit User Guide 241
IMAGING COMMANDS
The scanner is like a digital camera in the way it captures, manipulates, and trans-
fers images. The following commands allow you to alter the way the scanner per-
forms these functions.
Note: If you are using the scanner in a stand, you must set the In-Stand Sensor Mode to Off
in order to take images (see In-Stand Sensor Mode on page 124).
Single-Use Basis
Imaging Commands with their modifiers send instructions to the scanner on a sin-
gle-use basis, and take effect for a single image capture. Once that capture is com-
plete, the scanner reverts to its imaging default settings. If you want to
permanently change a setting, you must use the serial default commands (see
Chapter 13). When the serial default command is used, that selection becomes the
new, permanent setting for the scanner.
Command Syntax
Multiple modifiers and commands can be issued within one sequence. If additional
modifiers are to be applied to the same command, just add the modifiers to that
command. For example, to add 2 modifiers to the Image Snap command, such as
setting the Imaging Style to 1P and the Wait for Trigger to 1T, you would enter
IMGSNP1P1T.
Note: After processing an image capture command (IMGSNP or IMGBOX), you must follow
it with an IMGSHP command if you want to see it on your terminal.
To add a command to a sequence, each new command is separated with a semico-
lon. For example, to add the Image Ship command to the above sequence, you
would enter IMGSNP1P1T;IMGSHP.
The imaging commands are:
Image Snap - IMGSNP (page 242)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete

Related product manuals