EasyManuals Logo

Honeywell Xenon Series User Manual

Honeywell Xenon Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #290 background imageLoading...
Page #290 background image
270 Xenon/Granit User Guide
This response indicates that Codabar Coding Enable (CBRENA) has a range of val-
ues from 0 to 1 (off and on).
Example: What is the default value for Codabar Coding Enable?
Enter: cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: What is the device’s current setting for Codabar Coding Enable?
Enter: cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on.
Example: What are the device’s settings for all Codabar selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. First,
the scanner must be put in Manual Trigger Mode by scanning a Manual Trigger
Mode bar code (page 119), or by sending a serial menu command for triggering
(page 121). Once the scanner is in serial trigger mode, the trigger is activated and
deactivated by sending the following commands:
Activate: SYN T CR
Deactivate: SYN U CR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete

Related product manuals