162 Xenon/Granit User Guide
When setting up for specific symbologies (as opposed to all symbologies), the
specific symbology ID value counts as an added prefix or suffix character.
The maximum size of a prefix or suffix configuration is 200 characters, which
includes header information.
Add a Prefix or Suffix:
Step 1. Scan the Add Prefix or Add Suffix symbol (page 163).
Step 2. Determine the 2 digit hex value from the Symbology Charts (beginning
on page A-339) for the symbology to which you want to apply the prefix
or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”.
Step 3. Scan the 2 hex digits from the Programming Chart, beginning on page
353, or scan 9, 9 for all symbologies.
To add the Code I.D., scan 5, C, 8, 0.
To add the AIM I.D., scan 5, C, 8, 1.
To add the serial number, scan 5, C, 8, 8.
To add a backslash (\), scan 5, C, 5, C.
Note: When adding a backslash (\), you must scan 5C twice – once to create the leading
backslash and then to create the backslash itself.
Step 4. Repeat Steps 2 and 3 for every prefix or suffix character.
Step 5. Scan Save to exit and save, or scan Discard to exit without saving.
Repeat the steps above to add a prefix or suffix for another symbology.
Example: Add a Tab Suffix to All Symbologies
Step 1. Scan Add Suffix.
Step 2. Scan 9, 9 from the Programming Chart, beginning on page 353 to apply
this suffix to all symbologies.
Step 3. Scan 0, 9 from the Programming Chart, beginning on page 353. This
corresponds with the hex value for a horizontal tab, shown in the ASCII
Conversion Chart (Code Page 1252), beginning on page 342.
Step 4. Scan Save, or scan Discard to exit without saving.
Clear One or All Prefixes or Suffixes
You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology.
If you have been entering prefixes and suffixes for single symbologies, you can use
Clear One Prefix (Suffix) to delete a specific character from a symbology. When
you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are
deleted.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete