128 Xenon/Granit User Guide
Streaming Presentation In-Stand
This option is available when using In-Stand Sensor Mode, page 124. You may pro-
gram a specific Streaming Presentation Mode for in-stand scanning, and a Manual
Trigger mode for out-of-stand scanning. To do this, you must first scan the pre-
ferred Streaming Presentation mode (Normal, Enhanced, or Mobile Phone), then
scan the Manual Trigger mode (Normal, Enhanced, or Mobile Phone) you want to
use.
Mobile Phone Read Mode
When this mode is selected, your scanner is optimized to read bar codes from
mobile phone or other LED displays. However, the speed of scanning printed bar
codes may be slightly lower when this mode is enabled. You can enable Mobile
Phone Reading for either a hand held device, or for a hands-free (presentation)
application.
Note: Granit 1920I, 1980i and 1981i do not support these settings.
Note: To turn off Mobil Phone Read Mode, scan a Manual or Serial Trigger Mode bar code
(see page 119).
Hands Free Time-Out
The Scan Stand and Presentation Modes are referred to as “hands free” modes. If
the scanner’s trigger is pulled when using a hands free mode, the scanner changes
to manual trigger mode. You can set the time the scanner should remain in manual
trigger mode by setting the Hands Free Time-Out. Once the time-out value is
reached, (if there have been no further trigger pulls) the scanner reverts to the
original hands free mode.
Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-
300,000 milliseconds) from the Programming Chart, beginning on page 353, then
Save. Default = 5,000 ms.
Hand Held Scanning - Mobile
Phone
Streaming Presentation -
Mobile Phone
Hands Free Time-Out

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete