172 Xenon/Granit User Guide
Send all characters up to a particular character
F3 Include in the output message all characters from the input message, starting with
the character at the current cursor position and continuing to, but not including, the
search character “ss,” followed by an insert character. The cursor is moved forward
to the “ss” character. Syntax = F3ssxx where ss stands for the search character’s hex
value for its ASCII code, and xx stands for the insert character’s hex value for its
ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 342 for
decimal, hex and character codes.
F3 Example: Send all characters up to a particular character
Using the bar code above, send all characters up to but not including “D,” followed
by a carriage return.
Command string: F3440D
F3 is the “Send all characters up to a particular character” command
44 is the hex value for a 'D”
0D is the hex value for a CR
The data is output as:
1234567890ABC
<CR>
Send all characters up to a string
B9 Include in the output message all characters from the input message, starting with
the character at the current cursor position and continuing to, but not including, the
search string “s...s.” The cursor is moved forward to the beginning of the “s...s”
string. Syntax = B9nnnns...s where nnnn stands for the length of the string, and s...s
stands for the string to be matched. The string is made up of hex values for the
characters in the string. Refer to the ASCII Conversion Chart (Code Page 1252),
beginning on page 342 for decimal, hex and character codes.
B9 Example: Send all characters up to a defined string
Using the bar code above, send all characters up to but not including “AB.”
Command string: B900024142
B9 is the “Send all characters up to a string” command
0002 is the length of the string (2 characters)
41 is the hex value for A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete