EasyManuals Logo

Honeywell Xenon Series User Manual

Honeywell Xenon Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
178 Xenon/Granit User Guide
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
DEFGHIJ
<CR>
Search backward for a character
F9 Search the input message backward for “xx” character from the current cursor
position, leaving the cursor pointing to the “xx” character. Syntax = F9xx where xx
stands for the search character’s hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 342 for
decimal, hex and character codes.
Search forward for a string
B0 Search forward for “s” string from the current cursor position, leaving cursor
pointing to “s” string. Syntax = B0nnnnS where nnnn is the string length (up to
9999), and S consists of the ASCII hex value of each character in the match string.
For example, B0000454657374 will search forward for the first occurrence of the 4
character string “Test.”
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 342 for
decimal, hex and character codes.
B0 Example: Send bar code data that starts after a string of characters
Search for the letters “FGH” in bar codes and send all the data that follows, includ-
ing “FGH.” Using the bar code above:
Command string: B00003464748F10D
B0 is the “Search forward for a string” command
0003 is the string length (3 characters)
46 is the hex value for “F”
47 is the hex value for “G”
48 is the hex value for “H”
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
FGHIJ
<CR>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete

Related product manuals