Xenon/Granit User Guide 181
If the bar code has characters that the host application does not want included,
you can use the E4 command to replace those characters with something else. In
this example, you will replace the zeros in the bar code above with carriage returns.
Command string: E402300DF10D
E4 is the “Replace characters” command
02 is the total count of characters to be replaced, plus the replacement characters
(0 is replaced by CR, so total characters = 2)
30 is the hex value for 0
0D is the hex value for a CR (the character that will replace the 0)
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
1234
5678
ABC
<CR>
Stop replacing characters
E5 Terminates character replacement. Syntax = E5.
Compare characters
FE Compare the character in the current cursor position to the character “xx.” If
characters are equal, move the cursor forward one position. Syntax = FExx where xx
stands for the comparison character’s hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 342 for
decimal, hex and character codes.
Compare string
B2 Compare the string in the input message to the string “s.” If the strings are equal,
move the cursor forward past the end of the string. Syntax = B2nnnnS where nnnn
is the string length (up to 9999), and S consists of the ASCII hex value of each
character in the match string. For example, B2000454657374 will compare the
string at the current cursor position with the 4 character string “Test.”
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 342 for
decimal, hex and character codes.
Check for a number
EC Check to make sure there is an ASCII number at the current cursor position. The
format is aborted if the character is not numeric.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete

Related product manuals