Xenon/Granit User Guide 203
design, 3) a variation of Code 128 that supports concatenation of neighboring
symbols, and 4) the standard layout for bar codes on a blood product label. Use the
bar codes below to turn concatenation on or off. Default =Off.
Code 128 Redundancy
If you are encountering errors when reading Code 128 bar codes, you may want to
adjust the redundancy count. Redundancy adjusts the number of times a bar code
is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To
adjust the redundancy, scan the Code 128 Redundancy bar code below, then scan
a redundancy count between 0 and 10 on the Programming Chart, beginning on
page 353. Then scan the Save bar code. Default = 0.
Code 128 Message Length
Scan the bar codes below to change the message length. Refer to Message Length
Description (page 188) for additional information. Minimum and Maximum
lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Code 128 Append
This function allows the scanner to append the data from several Code 128 bar
codes together before transmitting them to the host computer. When the scanner
encounters a Code 128 bar code with the append trigger character(s), it buffers
On
* Off
Code 128 Redundancy
Minimum Message Length
Maximum Message Length

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
IP RatingIP42
ConnectivityUSB, RS-232, Keyboard Wedge, IBM 46XX, Synapse, USB-CDC
Decode Capabilities1D and 2D barcodes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Light LevelsAmbient light up to 100, 000 lux
Field of ViewHorizontal: 41.4°; Vertical: 32.2°
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Humidity5% to 95% (non-condensing)
Dimensions104 mm x 71 mm x 160 mm (4.1 in x 2.8 in x 6.3 in)
Drop ResistanceWithstands 50 drops at 1.8 m (6 ft) to concrete
Drop SpecificationWithstands 50 drops at 1.8 m (6 ft) to concrete

Related product manuals