Chapter 6, Call Processing Subsystem
CALL BIT Screen
NOTE: A mobile station must be actively connected on a voice channel to the Test Set (that
is, the
Connect annunciator lit) before you can attempt to send an order to a mobile
station.
Page
This field is used to initiate a page to the mobile station connected to the Test Set.
The Test Set must be in the active state (that is, Active annunciator must be lit)
and the MS Id information field on the CALL CONTROL screen must be correct
before you can attempt to page a mobile station.
[] Page
When lit, the Page annunciator indicates that the mobile station connected to the
Test Set is currently being paged on the forward control channel.
Register
This field is used to initiate a registration of the mobile station connected to the
Test Set. The Test Set must be in the active state (that is, the Active annunciator
must be lit) before you can attempt to register a mobile station.
[] Register
When lit, the Register annunciator indicates that the mobile station connected
to the Test Set is being commanded to register with the base station.
Release
This field is used to terminate an active voice channel connection to the mobile
station. When the Release field is selected, a mobile station control message
with a release order is sent to the mobile station on the forward voice channel. A
mobile station must be actively connected on a voice channel to the Test Set (that
is, the Connect annunciator must be lit) before you can attempt to send a release
order to the mobile station.
Set Message
This field is used to select the desired forward control channel or forward voice
channel message to be modified.