HP BladeSystem Insight Display troubleshooting  16 
HP BladeSystem Insight Display troubleshooting 
Insight Display overview 
The Insight Display enables the rack technician to configure the enclosure initially. It also provides 
information about the health and operation of the enclosure. See the HP BladeSystem Onboard 
Administrator User Guide for additional information. 
The Insight Display background color varies with the condition of the enclosure health: 
•  Blue—The Insight Display background illuminates blue when the enclosure UID is active. The enclosure 
UID is automatically turned on when the enclosure is powered up for the first time and can be turned on 
by selecting Turn Enclosure UID On from the Main Menu or by pressing the enclosure UID button on the 
rear of the enclosure. 
When the enclosure UID is on, the Insight Display flashes after 2 minutes of inactivity. Pressing any 
button on the Insight Display stops the flashing and reactivates the screen. 
•  Green—The Insight Display background illuminates green when no error or alert conditions exist and 
the enclosure is operating normally. After 2 minutes of inactivity, the Insight Display light turns off. 
Pressing any button on the Insight Display reactivates the screen. 
•  Amber—The Insight Display background illuminates amber when the Onboard Administrator detects 
an error or alert condition. Depending on the error, the component is displayed in red or yellow on the 
Health Summary screen. 
After 2 minutes of inactivity, the Insight Display background flashes amber, indicating an error or alert 
condition exists. If the enclosure UID is on and an error or alert condition exists, the Insight Display 
illuminates blue because the enclosure UID takes priority over the alert. Pressing any button on the 
Insight Display reactivates the screen. 
•  Dark (no power)—The Insight Display has a 2-minute inactivity period. If no action is taken and no alert 
condition exists, the enclosure UID is off, or the chat mode has not been activated, the screen light turns 
off after 2 minutes. Pressing any button on the Insight Display reactivates the screen.  
The Enclosure Health icon is located on the bottom left corner of every screen, indicating the enclosure health. 
To access the Health Summary screen from any Insight Display screen, navigate the cursor to the Enclosure 
Health icon and press OK. 
For information on driver and firmware updates, see the HP website (http://www.hp.com/go/blades/). 
 
Troubleshooting the Insight Display 
The Insight Display is the diagnostics panel for the enclosure. It is controlled by the Onboard Administrator 
and must be operating properly to troubleshoot the enclosure. This section provides methods to ensure that 
the Insight Display is operating properly. 
If the Insight Display is dark, press any Insight Display to wake up the display. If the Insight Display remains 
dark, then complete the procedures in this section.  
Observe the following guidelines when performing troubleshooting procedures: