Enclosure troubleshooting  47 
Step  Onboard Administrator errors action and verification 
 
Configuration 
When the IP address is updated for the new Onboard Administrator, then the hardware 
repair is complete. 
To complete the configuration, perform the following steps: 
1  If the OA1 IP address is 0.0.0.0 and is set for DHCP, then have the network 
administrator modify the DHCP server configuration to add the new OA MAC address. 
The OA MAC address is found in the new OA default DNS name. 
2  Log in to the new Onboard Administrator using the Administrator account and the new 
password. 
3  Verify that the Onboard Administrator firmware is the correct version. Update the 
Onboard Administrator firmware, if necessary. 
4  Complete the Onboard Administrator setup wizard or restore a previously saved 
enclosure configuration file. 
5  If not using LDAP for authentication, then manually update the passwords. 
 
 
 
Interconnect module troubleshooting 
Interconnect modules, including switches, pass-thrus, and aggregation modules, interact with the enclosure 
for management, power, and cooling. This section describes how to diagnose problems that occur during the 
interaction between interconnect modules and the enclosure. 
Insert interconnect blanks when interconnect slots are not used. 
For specific interconnect module troubleshooting procedures, see the component documentation. 
For specific component LED definitions and component identification, see "Component identification (on 
page 73)." 
 
Symptoms: Interconnect module errors 
  
Symptom  Initial step  Required steps 
The Insight Display reports error 
on suspect interconnect module.
—  To correct the issue, follow the Insight 
Display steps. 
An interconnect module does 
not power up. 
Interconnect modules are always 
powered up. However, if a port is 
unused or would present a 
configuration error, the port is 
disabled by the Onboard 
Administrator. 
Begin with step 1. 
An interconnect port not 
functioning properly. 
 
For troubleshooting information, see 
the interconnect module 
documentation. 
 
 
Procedures: Interconnect module errors 
 
 
CAUTION:   Some troubleshooting procedures require powering down an entire enclosure. To 
avoid possible data loss, always secure permission before powering down an enclosure.