Enclosure troubleshooting  41 
Step  Server blade errors action and verification 
 
Verification 
Wait for up to 2 minutes, then check the Insight Display. 
If the Insight Display illuminates and the Insight Display buttons operate properly, then 
install OA #Y, if present, in OA bay Y to complete the repair. 
If the issue still exists, continue to the next step. 
Step 18 
Action 
Replace the OA tray: 
1  Remove OA #X. 
2  Remove the OA tray. 
3  Install a service spare OA tray. 
4  Install OA #X in bay X. 
 
Verification 
Wait for up to 2 minutes, and then check the Insight Display. 
If the Insight Display illuminates and the Insight Display buttons operate properly, then 
install OA #Y, if present, in bay Y to complete the repair. 
If the issue still exists, then the OA tray did not fail. Continue to the next step. 
Step 19 
Action 
Contact an authorized service provider to complete the midplane assembly replacement 
(on page 66). 
 
 
Partner blade troubleshooting 
Partner blades are installed in a device bay. The partner blades are either connected to a server blade or 
interconnect module in the same enclosure. Partner blades cannot be powered down individually. This 
section describes the unique troubleshooting characteristics of those partner blades. 
For more information, see the component documentation. 
 
Symptoms: Partner blade errors 
  
Error indication  Initial step  Required steps 
Insight Display reports error on 
suspect partner blade 
—  To correct the issue, follow the 
Insight Display steps. 
Partner blade health LED is off 
—  Begin with step 1 
Partner blade health LED is 
amber 
For proper installation and support, most 
partner blades require a partner server 
blade to be installed and powered off 
during partner blade installation. If the 
partner blade is installed while the 
partner server blade is powered up, then 
power down the partner server blade 
before powering up the partner blade. 
Partner blades for interconnect modules 
require the interconnect module to be 
installed for operation. 
 
To correct the issue, follow the 
Insight Display steps. 
Partner blade health LED is 
green, but another LED on this 
partner blade is red 
—  For LED information, see the partner 
blade documentation.