Enclosure troubleshooting  36 
Error indication  Initial step  Required steps 
A server blade is powered up. 
The following conditions exist: 
  The power LED is green. 
  The health LED is green. 
  The Insight Display device bay 
status is blue. 
No iLO 2 IP address results in 
the following conditions: 
  No iLO 2 web or SSH 
access 
  No enclosure DVD-ROM 
drive support for this server 
blade 
  No server blade information 
provided to the Onboard 
Administrator 
  No remote console or 
remote media support 
The iLO 2 on this server blade has no 
IP address.  
To configure the iLO 2 IP address, 
reboot the server blade and use the 
iLO 2 ROM setup during POST. 
A server blade is powered up. 
The following conditions exist: 
  The power LED is green. 
  The health LED is green. 
  The Insight Display device bay 
status is red. 
This issue results in the following 
conditions: 
  The enclosure fan speed is 
elevated to protect the server 
blade. 
  The server blade cannot be 
powered up if it was 
manually powered down. 
  The Onboard Administrator 
report of server blade 
thermals and status is not 
accurate. 
The Onboard Administrator has lost 
power and cooling communication 
with iLO 2 for this server blade. 
To reset iLO 2, perform one of the 
following actions: 
  Log in to the iLO 2 GUI and reset 
iLO 2. 
  Use the OA CLI command for the 
bay, where N is the device bay 
number. 
reset server N 
Because the previous action requires 
restarting the server blade, always 
request permission to power down the 
server blade before performing this 
action: 
For an alternative method for resetting 
iLO 2, reseat the server blade. 
Reseating the server blade powers off 
the server blade and iLO 2.  
 
A server blade is powered up. 
The following conditions exist: 
  The power LED is green. 
  The health LED is flashing red. 
  The Insight Display device bay 
status is bright green. 
— 
The server blade failed to complete 
POST. To troubleshoot the memory 
installation, perform the following 
steps: 
1  Remove the server blade. 
2  Verify that the memory is installed 
according to the installation 
guidelines provided in the server 
blade documentation. 
3  Install the server blade in the 
original device bay. 
4  Review the IML for this server 
blade from OA GUI/CLI. 
5  Review the iLO log from this server 
blade for indicators.