Removing and replacing the LFF power switch moduleRemoving and replacing the LFF power switch module
ProcedureProcedure
1. Power down the server (Power down the server).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack ( Extend the server from the rack ).
Remove the server from the rack ( Remove the server from the rack ).
4. Remove the access panel ( Remove the access panel).
5. Remove all hot-plug hard drives ( Removing and replacing drives).
6. Remove the fan cage (Removing and replacing the fan cage ).
7. Disconnect all cables connecting the power switch module to the system board and other components.
8. Feeding the cables through the front of the server, remove the power switch module.
To replace the component, reverse the removal procedure.