EasyManua.ls Logo

HP SN3000B - Page 217

HP SN3000B
584 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fabric OS Administrator’s Guide 179
53-1002446-01
Configuration settings
8
[Active Security policies]
[cryptoDev]
[FICU SAVED FILES]
[Banner]
[End]
[Switch Configuration End : 0]
date = Tue Mar 1 21:28:52 2011
[Switch Configuration Begin : 1]
SwitchName = switch_2
Fabric ID = 1
[Boot Parameters]
[Configuration]
[Bottleneck Configuration]
[Zoning]
[Defined Security policies]
[Active Security policies]
[cryptoDev]
[FICU SAVED FILES]
[Banner]
[End]
[Switch Configuration End : 1]
Chassis section
There is only one chassis section within a configuration. It defines configuration data for chassis
components that affect the entire system, not just one individual logical switch. The chassis
section is included in non-Virtual Fabric modes only if you use the configUpload
-all command.
The chassis section specifies characteristics for the following software components:
• FC Routing – Fibre Channel Routing
• Chassis configuration – Chassis configuration
• FCOE_CH_CONF – FCoE chassis configuration
• UDROLE_CONF – User defined role configuration
• LicensesDB – License Database (slot based)
• DMM_WWN – Data migration manager World Wide Name configuration
• Licenses – (Feature based) Licenses configuration
• AGWWN_MAPPING_CONF – Access Gateway WWN mapping configuration

Table of Contents