304 Fabric OS Administrator’s Guide
53-1002446-01
Displaying bottleneck detection configuration details
13
Displaying bottleneck detection configuration details
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the bottleneckmon
--status command to display the details of bottleneck detection
configuration for the switch, which includes the following:
• Whether the feature is enabled
• Switch-wide parameters
• Per-port overrides, if any
• Excluded ports
Example
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold - 0.800
Severity threshold - 50.000
Switch-wide alerting parameters:
============================
Alerts - Yes
Latency threshold for alert - 0.100
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds
Per-port overrides for sub-second latency bottleneck criterion:
===============================================================
Slot Port TimeThresh SevThresh
=========================================
0 3 0.500 100.000
0 4 0.600 50.000
0 5 0.700 20.000
Per-port overrides for alert parameters:
========================================
Slot Port Alerts? LatencyThresh CongestionThresh Time (s)
QTime (s)
=============================================================================
=============
0 1 Y 0.990 0.900 3000 600
0 2 Y 0.990 0.900 4000 600
0 3 Y 0.990 0.900 4000 600
Excluded ports:
===============
Slot Port
============
0 2
0 3
0 4