Table 35 Error codes (part code 03122) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WSpecify the volumes that have the same
CLPR, then retry the operation.
The selected volumes cannot be specified
as a pool volume, because different
CLPRs selected coexist.
10602303122
WRestore the status of the pool, then retry
the operation.
The operation cannot be executed,
because the specified pool is blocked.
10602403122
WDelete the pool.The operation cannot be executed,
because the specified pool is blocked.
10602503122
WRestore the status of the pool volume,
then retry the operation.
The operation cannot be executed,
because the pool volume is blocked.
10602603122
WCheck the usage rate of the pool, then
retry the operation.
The operation cannot be executed,
because the pool usage exceeds the
threshold.
10602703122
WStop the shrinking operation on the pool,
then retry the operation.
The operation cannot be executed,
because the specified pool is in shrinking
operation.
10602803122
WCheck the status of the pool, then retry
the operation.
The operation cannot be executed,
because the specified pool is in Normal
status.
10602903122
WDelete the associated Thin Provisioning
volume, then retry the operation.
The operation cannot be executed,
because the specified pool is associated
with a Thin Provisioning volume.
10603003122
WCheck the pool usage, then retry the
operation.
The operation cannot be executed,
because the specified pool is being used.
10603103122
WCheck the status of the pool.The operation cannot be executed,
because the specified pool is not in
shrinking operation.
10603203122
WCheck the pool type.The operation cannot be executed,
because the specified pool is defined as
the pool of Snapshot.
10603303122
WCheck the setting of pool capacity, pool
usage, depletion threshold, warning
threshold, and system threshold, then
retry the operation.
The shrinking operation cannot be
performed on the specified pool because
the usage rate after shrinking becomes
higher than the highest threshold set
among the depletion threshold, the
warning threshold, and the system
threshold.
10603403122
WSelect a volume other than the top pool
volume.
The operation cannot be executed,
because the top pool volume has been
selected.
10603503122
WCheck the state of the specified pool
volumes, then retry the operation.
The operation cannot be executed,
because the specified pool volumes
contain an abnormal pool volume.
10603603122
WExecute any of the following actions,
then retry the operation.
• Increase the pool capacity by adding
pool volume(s).
• Reduce the pool usage.
The setting cannot be executed, because
the specified pool has no free space.
10603703122
WSelect one table row.No table row, or two or more table rows
are selected.
10603803122
Part code 03122 97