Event
code
Message and description Details and solution
4086 Move operation failed due to inability to
access the internal library database.
1. Verify that the network the library is
connected to is not experiencing
abnormal loads, such as packet storms
or excessive polling.
2. Verify that the library is running the latest
firmware version.
3. Power cycle the library.
4087 Key server token is over 90% full. Obtain a new key server token and seed it
with the keys needed for current use. See
the encryption kit user guide for instructions.
4088 Library not properly calibrated. This might
cause media movement failures.
Some chassis calibration data does not
match the installed robotic assembly.
1. Verify that the library is running the
current firmware version.
2. Power cycle the library. The library
initiates the calibration operation during
power-on. If the calibration operation
does not begin during the power-on or
the error persists, initiate the auto
calibrate operation from the
Maintenance > Auto Calibration RMI
screen.
For more information about auto calibration,
see Calibrating the library on page 105.
NOTE:
The Auto Calibration routine can take up to
15 minutes per module. The library will be
offline to hosts while the routine is running.
4089 Auto calibration of one or more modules
failed. Library not properly calibrated. Lack
of calibration might cause media movement
failures.
4090 Auto calibration of one or more modules
failed. Library not properly calibrated. Lack
of calibration might cause media movement
failures.
4091 Auto calibration of one or more modules
failed. Library not properly calibrated. Lack
of calibration might cause media movement
failures.