161
IPv6 Virtual Router Information:
Running Mode : Load Balance
Total number of virtual routers : 1
Interface Vlan-interface2
VRID : 1 Adver Timer : 100
Admin Status : Up State : Backup
Config Pri : 100 Running Pri : 100
Preempt Mode : Yes Delay Time : 500
Become Master : 410ms left
Auth Type : None
Virtual IP : FE80::10
1::10
Member IP List : FE80::3 (Local, Backup)
FE80::1 (Master)
FE80::2 (Backup)
Forwarder Information: 3 Forwarders 2 Active
Config Weight : 255
Running Weight : 255
Forwarder 01
State : Active
Virtual MAC : 000f-e2ff-4011 (Take Over)
Owner ID : 0000-5e01-1101
Priority : 85
Active : local
Forwarder 02
State : Listening
Virtual MAC : 000f-e2ff-4012 (Learnt)
Owner ID : 0000-5e01-1103
Priority : 85
Active : FE80::2
Forwarder 03
State : Active
Virtual MAC : 000f-e2ff-4013 (Owner)
Owner ID : 0000-5e01-1105
Priority : 255
Active : local
Forwarder Weight Track Information:
Track Object : 1 State : Positive Weight Reduced : 250
The output shows that when VLAN interface 3 on Switch A fails, the weights of the VFs on
Switch A drop below the lower limit of failure. All VFs on Switch A transit to the Initialized state
and cannot forward traffic. The VF for MAC address 000f-e2ff-4011 on Switch C becomes the
AVF to forward traffic.
# When the timeout timer (about 1800 seconds) expires, display detailed information about
VRRP group 1 on Switch C.
[SwitchC-Vlan-interface2] display vrrp ipv6 verbose
IPv6 Virtual Router Information:
Running Mode : Load Balance
Total number of virtual routers : 1
Interface Vlan-interface2

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)