7
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Configure the errored frame
period event detection
window.
oam global
errored-frame-period window
window-value
By default, the errored frame
period event detection window is
10000000.
3. Configure the errored frame
period event triggering
threshold.
oam global
errored-frame-period threshold
threshold-value
By default, the errored frame
period event triggering threshold
is 1.
To configure errored frame period event detection on a port:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Enter Layer 2/Layer 3
Ethernet port view.
interface
interface-type
interface-number
N/A
3. Configure the errored frame
period event detection
window.
oam errored-frame-period
window
window-value
By default, an interface uses the
value configured globally.
4. Configure the errored frame
period event triggering
threshold.
oam errored-frame-period
threshold
threshold-value
By default, an interface uses the
value configured globally.
Configuring errored frame seconds event detection
CAUTION:
Make sure the errored frame seconds triggering threshold is less than the errored frame seconds
detection window. Otherwise, no errored frame seconds event can be generated.
An errored frame seconds event occurs when the number of times that errored frame seconds are
detected on a port in the detection window (specified detection interval) exceeds the predefined
threshold.
You can configure this command in system view or port view. The configuration in system view takes
effect on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
To configure errored frame seconds event detection globally:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Configure the errored frame
seconds event detection
window.
oam global
errored-frame-seconds window
window-value
By default, the errored frame
seconds event detection window
is 60000 milliseconds.
3. Configure the errored frame
seconds event triggering
threshold.
oam global
errored-frame-seconds
threshold
threshold-value
By default, the errored frame
seconds event triggering
threshold is 1.
To configure errored frame seconds event detection on a port:
Step Command Remarks
1. Enter system view.
system-view
N/A

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% (noncondensing)
LatencyLess than 1 µs