EasyManuals Logo

HPE FlexFabric 5700 Series Configuration Guide

HPE FlexFabric 5700 Series
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #186 background imageLoading...
Page #186 background image
180
Interface Vlan-interface2
VRID : 1 Adver Timer : 500
Admin Status : Up State : Master
Config Pri : 110 Running Pri : 110
Preempt Mode : Yes Delay Time : 500
Auth Type : Simple Key : ******
Virtual IP : 10.1.1.10
Virtual MAC : 0000-5e00-0101
Master IP : 10.1.1.1
VRRP Track Information:
Track Object : 1 State : Positive Pri Reduced : 30
# Display detailed information about VRRP group 1 on Switch B.
[SwitchB-Vlan-interface2] display vrrp verbose
IPv4 Virtual Router Information:
Running Mode : Standard
Total number of virtual routers : 1
Interface Vlan-interface2
VRID : 1 Adver Timer : 500
Admin Status : Up State : Backup
Config Pri : 100 Running Pri : 100
Preempt Mode : Yes Delay Time : 500
Become Master : 2200ms left
Auth Type : Simple Key : ******
Virtual IP : 10.1.1.10
Master IP : 10.1.1.1
The output shows that in VRRP group 1, Switch A is the master, and Switch B is a backup. Switch A
forwards packets from Host A to Host B.
# Disconnect the link between Switch A and Switch C, and verify that Host A can still ping Host B.
(Details not shown.)
# Display detailed information about VRRP group 1 on Switch A.
IPv4 Virtual Router Information:
Running Mode : Standard
Total number of virtual routers : 1
Interface Vlan-interface2
VRID : 1 Adver Timer : 500
Admin Status : Up State : Backup
Config Pri : 110 Running Pri : 80
Preempt Mode : Yes Delay Time : 500
Become Master : 2200ms left
Auth Type : Simple Key : ******
Virtual IP : 10.1.1.10
Master IP : 10.1.1.2
VRRP Track Information:
Track Object : 1 State : Negative Pri Reduced : 30
# Display detailed information about VRRP group 1 on Switch B.
[SwitchB-Vlan-interface2] display vrrp verbose
IPv4 Virtual Router Information:

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% (noncondensing)
LatencyLess than 1 µs

Related product manuals