X509v3 CRL Distribution Points:
Full Name:
URI:http://192.168.40.130/pki/pub/crl/cacrl.crl
Signature Algorithm: sha256WithRSAEncryption
53:69:66:5f:93:f0:2f:8c:54:24:8f:a2:f2:f1:29:fa:15:16:
90:71:e2:98:e3:5c:c6:e3:d4:5f:7a:f6:a9:4f:a2:7f:ca:af:
c4:c8:c7:2c:c0:51:0a:45:d4:56:e2:81:30:41:be:9f:67:a1:
23:a6:09:50:99:a1:40:5f:44:6f:be:ff:00:67:9d:64:98:fb:
72:77:9e:fd:f2:4c:3a:b2:43:d8:50:5c:48:08:e7:77:df:fb:
25:9f:4a:ea:de:37:1e:fb:bc:42:12:0a:98:11:f2:d9:5b:60:
bc:59:72:04:48:59:cc:50:39:a5:40:12:ff:9d:d0:69:3a:5e:
3a:09:5a:79:e0:54:67:a0:32:df:bf:72:a0:74:63:f9:05:6f:
5e:28:d2:e8:65:49:e6:c7:b5:48:7d:95:47:46:c1:61:5a:29:
90:65:45:4a:88:96:e4:88:bd:59:25:44:3f:61:c6:b1:08:5b:
86:d2:4f:61:4c:20:38:1c:f4:a1:0b:ea:65:87:7d:1c:22:be:
b6:17:17:8a:5a:0f:35:4c:b8:b3:73:03:03:63:b1:fc:c4:f5:
e9:6e:7c:11:e8:17:5a:fb:39:e7:33:93:5b:2b:54:72:57:72:
5e:78:d6:97:ef:b8:d8:6d:0c:05:28:ea:81:3a:06:a0:2e:c3:
79:05:cd:c3
To display detailed information about the CA certificate, use the display pki certificate domain
command.
Troubleshooting PKI configuration
This section provides troubleshooting information for common problems with PKI.
Failed to obtain the CA certificate
Symptom
The CA certificate cannot be obtained.
Analysis
• The network connection is down, for example, because the network cable is damaged or the
connectors have bad contact.
• No trusted CA is specified.
• The certificate request URL is incorrect or not specified.
• The system time of the device is not synchronized with the CA server.
• The source IP address of the PKI protocol packets is not specified or is incorrect.
• The fingerprint of the root CA certificate is illegal.
Solution
1. Check for and fix any network connection problems.
2. Verify that the required configurations are correct.
3. Use ping to verify that the registration server is reachable.
4. Synchronize the system time of the device with the CA server.

Table of Contents

Other manuals for HPE FlexFabric 5940 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5940 SERIES and is the answer not in the manual?

HPE FlexFabric 5940 SERIES Specifications

General IconGeneral
BrandHPE
ModelFlexFabric 5940 SERIES
CategorySwitch
LanguageEnglish

Related product manuals