No. Data
2 Alarm severity:
l 1: Critical
l 2: Major
l 3: Minor
l 4: Warning
l 5: Indeterminate
l 6: Cleared
3
Period after which a generated alarm is reported and period after which a generated
recovery alarm is reported
4 Interface enabled with alarm filtering
 
7.3.2 Setting the Alarm Severity Level
You can change the default alarm severity level.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
alarm
The alarm view is displayed.
Step 3 Run:
alarm-name alarm-name severity severity
The alarm severity level is set.
If you focus on certain types of alarms, you can set the highest severity level for these types of
alarms and configure filtering conditions. In this manner, the system reports only these types of
alarms to the NMS.
----End
7.3.3 Configuring Delaying Alarm Reporting
To control the frequency at which alarms are reported, you can set a period after which a
generated alarm is reported.
Procedure
Step 1 Run:
system-view