The system view is displayed.
Step 2 Run:
alarm
The alarm view is displayed.
Step 3 Run:
delay-suppression enable
The delayed alarm reporting function is enabled.
By default, this function is enabled to prevent intermittent alarms and repeated alarms from being
reported during the delay period.
Step 4 Run:
suppression alarm-name alarm-name { cause-period cause-seconds | clear-period
clear-seconds }
The period after which a generated alarm is reported is set.
After such a period is set for an alarm, there are the following situations:
l If no recovery alarm is generated during the period, the alarm is not reported to the NMS
until the period expires.
l If a recovery alarm is generated during this period, the alarm and its recovery alarm are both
deleted from the alarm queue and will not be reported to the NMS.
You can use the parameter cause-period cause-seconds to set the period after which a generated
alarm is reported.
You can use the parameter clear-period clear-seconds to set the period after which a generated
recovery alarm is reported.
----End
7.3.4 Configuring Correlated Alarm Suppression
After correlated alarm suppression is configured, the system filters out non-root-cause alarms
and reports only root-cause alarms to the NMS.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
alarm
The alarm view is displayed.
Step 3 Run:
correlation-analyze enable
Correlated alarm suppression is enabled.
Huawei AR150&200 Series Enterprise Routers
Configuration Guide - Device Management 7 Fault Management
Issue 02 (2012-03-30) Huawei Proprietary and Confidential