Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
event
The event view is displayed.
Step 3 Run:
clear event all
Event messages are cleared.
----End
7.6 Configuration Examples
This section provides examples for configuring fault management, including networking
requirements, configuration notes, and configuration roadmap.
7.6.1 Example for Configuring Alarm Management
In this example, delayed alarm reporting and correlated alarm suppression are configured to
filter out unimportant alarms.
Networking Requirements
A user logs in to the router to perform alarm management.
Configuration Notes
None.
Configuration Roadmap
The configuration roadmap is as follows:
1. Set alarm parameters.
2. Set a period after which a generated alarm is reported.
3. Configure interface-based alarm filtering.
Data Preparation
To complete the configuration, you need the following data:
l Alarm name
l Alarm severity level
l Period after which a generated alarm is reported
l Type and number of the interface on which alarms are filtered
Huawei AR150&200 Series Enterprise Routers
Configuration Guide - Device Management 7 Fault Management
Issue 02 (2012-03-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
121