l Optional: Set the power-off time range of a PoE interface.
1. Run:
system-view
The system view is displayed.
2. Run:
time-range time-name { start-time to end-time days | from time1 date1
[ to time2 date2 ] }
The power-off time range of a PoE interface is set.
NOTE
To configure multiple time ranges with the same name on the AR150/200, run the preceding
command with the same value of time-name repeatedly.
3. Run:
interface interface-type interface-number
The interface view is displayed.
4. Run:
poe power-off time-range time-name
The power-off time range takes effect on the interface.
l Optional: Enable an interface to check PD compatibility.
NOTE
Before enabling an interface to check compatibility of PDs, you must enable PoE on the PSE. After
this function is enabled, the interface can detect the PDs that do not comply with IEEE 802.3af or
802.3at.
1. Run:
system-view
The system view is displayed.
2. Run:
interface interface-type interface-number
The interface view is displayed.
3. Run:
poe legacy enable
The interface is enabled to check PD compatibility.
By default, an interface does not check PD compatibility.
----End
3.3.4 Checking the Configuration
After the PoE configurations are complete, you can view the PoE power status, device
information, and PoE configuration on an interface.
Prerequisites
The PoE power supply and PoE board are installed, and the PoE function is configured.