Huawei AR3200 Series - Creating an Eth-Trunk Interface

Huawei AR3200 Series
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 1-2 Network diagram of link aggregation in manual load balancing mode
RouterA
RouterB
Eth-Trunk 1 Eth-Trunk 1
Eth-Trunk
Pre-configuration Tasks
Before configuring an Eth-Trunk in manual load balancing mode, complete the following tasks:
l Powering on the AR3200
l Creating an Eth-Trunk
Data Preparation
To configure an Eth-Trunk in manual load balancing mode, you need the following data.
No. Data
1 Number of the Eth-Trunk in manual load balancing mode
2 Types and numbers of the member interfaces
1.3.2 Creating an Eth-Trunk Interface
Context
Eth-Trunk interfaces increase bandwidth and improve transmission reliability. You can
configure Layer 2 and Layer 3 Eth-Trunk interfaces for different applications on a network.
Procedure
l Creating a Layer 2 Eth-Trunk interface
1. Run:
system-view
The system view is displayed.
2. Run:
interface eth-trunk trunk-id
A Layer 2 Eth-Trunk interface is created.
By default, an Eth-Trunk interface works in Layer 2 mode.
l Creating a Layer 3 Eth-Trunk interface
1. Run:
system-view
The system view is displayed.