Category Component Maximum Power
Consumption
CX621 154 W
Management modules MM910 36 W
Fan modules - 65 W
PSU Configuration Policies
AC PSU
Table 2-7 Configuration policies for the 3000 W AC PSU (220 V AC to 240 V AC input
voltage at 50 Hz or 60 Hz; 3000 W output power)
Power Range
Redundancy
Mode
PSU Qty. Recommended Slots
P < 3000 W Non-
redundancy
1 PSU1
3000 W < P < 6000 W Non-
redundancy
2 PSU1, PSU4
6000 W < P < 9000 W Non-
redundancy
3 PSU1, PSU2, PSU4
9000 W < P < 12000 W Non-
redundancy
4 PSU1, PSU2, PSU4, PSU5
12000 W < P < 15000 W Non-
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
15000 W < P < 18000 W Non-
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
P < 3000 W 1+1
redundancy
2 PSU1, PSU4
3000 W < P < 6000 W 2+1
redundancy
3 PSU1, PSU2, PSU4
6000 W < P < 9000 W 3+1
redundancy
4 PSU1, PSU2, PSU4, PSU5
9000 W < P < 12000 W 4+1
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
12000 W < P < 15000 W 5+1
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
3000 W < P < 6000 W 2+2
redundancy
4 PSU1, PSU2, PSU4, PSU5
E9000 Server
User Guide
2 Overview
Issue 25 (2019-11-30) Copyright © Huawei Technologies Co., Ltd. 22