Power Range Redundancy
Mode
PSU Qty. Recommended Slots
6000 W < P < 9000 W 3+3
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
Table 2-8 Configuration policies for the 3000 W AC PSU (220 V AC to 220 V AC input
voltage at 50 Hz or 60 Hz; 2500 W output power)
Power Range
Redundancy
Mode
PSU Qty. Recommended Slots
P < 2500 W Non-
redundancy
1 PSU1
2500 W < P < 5000 W Non-
redundancy
2 PSU1, PSU4
5000 W < P < 7500 W Non-
redundancy
3 PSU1, PSU2, PSU4
7500 W < P < 10000 W Non-
redundancy
4 PSU1, PSU2, PSU4, PSU5
10000 W < P < 12500 W Non-
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
12500 W < P < 15000 W Non-
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
P < 2500 W 1+1
redundancy
2 PSU1, PSU4
2500 W < P < 5000 W 2+1
redundancy
3 PSU1, PSU2, PSU4
5000 W < P < 7500 W 3+1
redundancy
4 PSU1, PSU2, PSU4, PSU5
7500 W < P < 10000 W 4+1
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
10000 W < P < 12500 W 5+1
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
2500 W < P < 5000 W 2+2
redundancy
4 PSU1, PSU2, PSU4, PSU5
5000 W < P < 7500 W 3+3
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
E9000 Server