Table 2-9 Configuration policies for the 3000 W PSU (100 V AC to 130 V AC input voltage
at 50 Hz or 60 Hz; 1200 W output power)
Power Range Redundancy
Mode
PSU Qty. Recommended Slots
P < 1200 W Non-
redundancy
1 PSU1
1200 W < P < 2400 W Non-
redundancy
2 PSU1, PSU4
2400 W < P < 3600 W Non-
redundancy
3 PSU1, PSU2, PSU4
3600 W < P < 4800 W Non-
redundancy
4 PSU1, PSU2, PSU4, PSU5
4800 W < P < 6000 W Non-
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
6000 W < P < 7200 W Non-
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
P < 1200 W 1+1
redundancy
2 PSU1, PSU4
1200 W < P < 2400 W 2+1
redundancy
3 PSU1, PSU2, PSU4
2400 W < P < 3600 W 3+1
redundancy
4 PSU1, PSU2, PSU4, PSU5
3600 W < P < 4800 W 4+1
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
4800 W < P < 6000 W 5+1
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
1200 W < P < 2400 W 2+2
redundancy
4 PSU1, PSU2, PSU4, PSU5
2400 W < P < 3600 W 3+3
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
Table 2-10 Configuration policies for the 2000 W AC PSU (220 V AC to 240 V AC input
voltage at 50 Hz or 60 Hz; 2000 W output power)
Power Range
Redundancy
Mode
PSU Qty. Recommended Slots
P < 2000 W Non-
redundancy
1 PSU1
E9000 Server
User Guide
2 Overview
Issue 25 (2019-11-30) Copyright © Huawei Technologies Co., Ltd. 24