Power Range Redundancy
Mode
PSU Qty. Recommended Slots
2000 W < P < 4000 W Non-
redundancy
2 PSU1, PSU4
4000 W < P < 6000 W Non-
redundancy
3 PSU1, PSU2, PSU4
6000 W < P < 8000 W Non-
redundancy
4 PSU1, PSU2, PSU4, PSU5
8000 W < P < 10000 W Non-
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
10000 W < P < 12000 W Non-
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
P < 2000 W 1+1
redundancy
2 PSU1, PSU4
2000 W < P < 4000 W 2+1
redundancy
3 PSU1, PSU2, PSU4
4000 W < P < 6000 W 3+1
redundancy
4 PSU1, PSU2, PSU4, PSU5
6000 W < P < 8000 W 4+1
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
8000 W < P < 10000 W 5+1
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
2000 W < P < 4000 W 2+2
redundancy
4 PSU1, PSU2, PSU4, PSU5
4000 W < P < 6000 W 3+3
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
Table 2-11 Configuration policies for the 2000 W AC PSU (200 V AC to 220 V AC input
voltage at 50 Hz or 60 Hz; 1800 W output power)
Power Range
Redundancy
Mode
PSU Qty. Recommended Slots
P < 1800 W Non-
redundancy
1 PSU1
1800 W < P < 3600 W Non-
redundancy
2 PSU1, PSU4
3600 W < P < 5400 W Non-
redundancy
3 PSU1, PSU2, PSU4
E9000 Server
User Guide
2 Overview