Power Range Redundancy
Mode
PSU Qty. Recommended Slots
5400 W < P < 7200 W Non-
redundancy
4 PSU1, PSU2, PSU4, PSU5
7200 W < P < 9000 W Non-
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
9000 W < P < 10800 W Non-
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
P < 1800 W 1+1
redundancy
2 PSU1, PSU4
1800 W < P < 3600 W 2+1
redundancy
3 PSU1, PSU2, PSU4
3600 W < P < 5400 W 3+1
redundancy
4 PSU1, PSU2, PSU4, PSU5
5400 W < P < 7200 W 4+1
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
7200 W < P < 9000 W 5+1
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
1800 W < P < 3600 W 2+2
redundancy
4 PSU1, PSU2, PSU4, PSU5
3600 W < P < 5400 W 3+3
redundancy
6 PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
Table 2-12 Configuration policies for the 2000 W AC PSU (100 V AC to 130 V AC input
voltage at 50 Hz or 60 Hz; 800 W output power)
Power Range
Redundancy
Mode
PSU Qty. Recommended Slots
P < 800 W Non-
redundancy
1 PSU1
800 W < P < 1600 W Non-
redundancy
2 PSU1, PSU4
1600 W < P < 2400 W Non-
redundancy
3 PSU1, PSU2, PSU4
2400 W < P < 3200 W Non-
redundancy
4 PSU1, PSU2, PSU4, PSU5
3200 W < P < 4000 W Non-
redundancy
5 PSU1, PSU2, PSU3,
PSU4, PSU5
E9000 Server
User Guide
2 Overview