EasyManua.ls Logo

Huawei NE40E - Page 90

Huawei NE40E
1058 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Description
1 Hardware Description
Issue 01 (2018-05-03)
76
Item
Specification
Typical heat dissipation
DC: 2595.5 BTU/hour (fully configured with
LPUF-51s)
AC: 3082.2 BTU/hour (fully configured with
LPUF-51s)
DC: 2984.9 BTU/hour (fully configured with
LPUF-120s)
AC: 3471.5 BTU/hour (fully configured with
LPUF-120s)
DC input voltage
input voltage range: 38.4 V to 72 V
input rated voltage: 48 V/ 60 V
AC input voltage
input voltage range: 180 V to 264 V
input rated voltage: 200 V to 240 V
MTBF
27.44 years
MTTR
0.5 hours
Availability
0.99999792
Slot quantity
5
Redundant MPUs
1:1
Redundant Switch fabrics
N/A
Redundant fans
Support for proper fan operation in case of a single fan
failure for a short period at 40°C (104°F)
Redundant power supply
1+1
Forwarding performance
225 Mpps (LPUF-51)
360 Mpps (LPUF-120)
Switching capacity
1.08 Tbps
Operating temperature
Long-term: C to 45°C (32°F to 113°F)
Short-term: C to +55°C (23°F to131°F)
Remark: Restriction on the temperature variation
rate: 30°C/hour (86°F/h)
Storage temperature
40°C to +70°C (40°F to +158°F)
Relative operating humidity
Long term: 5% to 85% RH, non-condensing
Short term: 5% to 95% RH, non-condensing

Table of Contents