EasyManua.ls Logo

Husky Altanium Neo5 - Automatic Thermocouple Wiring

Husky Altanium Neo5
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
v 1.0 — August 2018 Altanium Neo5
Page 96
NOTE: "Not tested", could be because the zone was not selected, or because one or two test
types (heaters, sensors, or wiring) were not checked. "Test did not complete", means
the test timed out or the user stopped the test.
8.3.1 Automatic Thermocouple Wiring
Thermocouples can be inadvertently cross-wired in the mold, where the thermocouple for
one heater becomes connected with another heater, and vice versa.
The Neo5 wiring test checks the thermocouple/heater wiring and determines whether the
wiring is correct. When the test is complete and if an error was found, the zone with the error
will display Failed, followed by the zone number with the maximum response in the wiring
column. Also, the Re-Wire button in the Mold Test, Settings screen will be enabled.
To automatically rewire thermocouples:
1. If necessary, on the bottom of the Mold Test screen, touch .
2. On the Settings screen, touch the Rewire button to
automatically reassign the mold thermocouples to their correct zones.
NOTE: This information is saved with the current mold setup.
G/F The ground fault test tests for an earth leakage in each zone. Earth
leakage values are displayed as follows:
? = Test did not complete.
- - - = No current sensor for this zone.
OK = Passed.
Fail = Failed (measured a leakage value that exceeded the Earth
Leakage Limit setting in Quick Set).
B/O The bake out test tests for moisture in each heater. Bake out values are
displayed as follows:
? = Test did not complete.
- - - = No current sensor for this zone.
OK = Passed.
Fail = Failed (measured a leakage value that exceeded the Bake Out
Limit setting in the System Setup screen).
Leakage The measured earth leakage in amps.
? = Test did not complete.
Time Time taken to test each zone.
? = Test did not complete.
Item Description