Page 114
v 1.0 — August 2018 Altanium Neo5
11.1.1 Setting Soak Timers
At the end of each stage during staged startup or shutdown, when all the zones are at the
stage setpoint, they can be left to “soak” for a specified time before the next stage begins. Use
the Staging screen to change the soak time lengths.
NOTE: It is not necessary to assign a soak time to each stage. To avoid a delay between when
a stage has reached setpoint and before the following stage is activated, set the timer
to 00:00:00.
NOTE: It is not necessary to select zones to set the soak timer.
1. On the Staging screen, touch on the Staged Startup button to show the drop down
menu.
2. Touch the box to the right of the stage 1 soak timer.
3. Use the dialog box to set the soak time, then .
Item Description
Run Last Stage Indefinitely If this setting is enabled, all zones in the last assigned stage will
not change to their normal setpoint once all zones have achieved
the stage setpoint and the soak timer has expired.
Stage x Soak Timer The time the zones stay “soak” at the stage setpoint before the
next stage begins.
At Temp Window The stage will be At Temperature when the setpoint is within the
At Temperature window.

Table of Contents