v 1.0 — August 2018 Altanium Neo5
Page 4
1.5 Environmental Operating Specifications
The following are the environmental operating specifications for the Altanium Neo5
operator interface:
For Indoor use only.
Operating Temperature: 5 to 40 °C (41 to 104 °F)
Operating Humidity: 0% to 90% RH, Non-Condensing
Altitude: up to 2000 m (6562 ft)
Pollution Degree: PD2
Overvoltage Category: OVII
1.6 Equipment Ratings
Ratings for the entire Neo5 can be found on the nameplate attached to the back of the
controller.
The following are the equipment ratings for the Neo5 operator interface only:
Supply Voltage: 100 to 240 VAC +/- 10%, single phase
Frequency: 47 to 63 Hz
Power Rating: 130 W
Line Brown Red
Line Gray White
Description Wire Color
DANGER!
Electrocution and/or mechanical hazard - risk of death or serious injury and possible
damage to the equipment.
Incorrectly wiring the controller could cause death or serious injury and/or damage to
the controller or hot runner. Only qualified personnel should connect the electrical
power supply. All work must conform to applicable local electrical codes.
CAUTION!
Mechanical hazard – risk of equipment damage. Falling or spraying liquid, including oil
or water, could damage the equipment. Do not spray wash.

Table of Contents