Page 129
User Guide v 1.0 — August 2018 Altanium Neo5
The table that follows shows the connection detail for all the inputs wired to accept voltage
from an external source.
14.2.4 Output Connector Pin-Out
The table that follows shows the connection detail for all of the outputs.
CAUTION!
Electrical hazard - risk of damage to the equipment. DO NOT apply a voltage greater
than 30VDC to any of the inputs. Doing so could damage the Neo5.
Digital Inputs (Wiring to Accept Voltage from External Source)
Connector/Pin Field Cable Wire Color External Voltage Source Signal Function
Input / 1 Black Not Used
Remote Standby
Input / 2 Red +5-30VDC
Input / 3 White Not Used
Remote Boost
Input / 4 Green +5-30VDC
Input / 5 Orange Not Used
Remote Start
Input / 6 Blue +5-30VDC
Input / 7 Brown Not Used
Remote Stop
Input / 8 Yellow +5-30VDC
Input / 9 Violet -VDC Reference
CAUTION!
Electrical hazard - risk of damage to the equipment. DO NOT apply a voltage greater
than 30VDC at 2 amps to any of the Outputs. Doing so could damage the Neo5.
Digital Outputs
Connector/Pin Field Cable Wire Color Signal Function
Input / 1 Black
Alarm
Input / 2 Red
Input / 3 White
Abort (PCM)
Input / 4 Green
Input / 5 Orange
At Temperature
Input / 6 Blue

Table of Contents