v 1.0 — August 2018 Altanium Neo5
Page 82
Control Mode — ART automatically adjusts the control algorithm to suit different heater
requirements. If a zone is not controlling properly the system allows users to switch from the
automatically adjusted ART algorithm to an algorithm that can be manually adjusted (PID).
P-Proportional — This is the proportional term value used by the control algorithm. Possible
values are 0 to 250.
I-Integral — This is the integral term value used by the control algorithm. Possible values are
0 to 250.
D-Derivative — This is the derivative term value used by the control algorithm. Possible
values are 0 to 250.
PID values are set in the ART settings drop down menu.
7.5.12 Art Settings