EasyManuals Logo

Hypertherm HyPerformance Plasma HPR800XD User Manual

Hypertherm HyPerformance Plasma HPR800XD
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
OperatiOn
HPR800XD Auto Gas 806500 4-107
Aluminum
N
2
Plasma / N
2
Shield
600 A
220707220637 220709220885 220405220859 220571
Metric
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
30 10 60 35 24 1.8 0.07 1270 50 81
Note: Pierce complete must be turned OFF for all 600 A processes.
Flow rates – lpm/scfh
N
2
Preflow 110 / 232
Cutflow 167 / 353
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Transfer
Height
Initial Pierce
Height
Pierce
Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm mm
Factor
%
Seconds
N
2
N
2
43 13 50 34
40 185 9.5 1448 19.1 25.4 266 2.0
45 196 12.7 1248
Edge start
50 195 10.2 1048
60 209
12.7
832
80 212 600
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Transfer
Height
Initial Pierce
Height
Pierce
Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in in
Factor
%
Seconds
N
2
N
2
43 13 50 34
1-1/2 185 0.375 60 0.75 1.0 266 2.0
1-3/4 196 0.500 50
Edge start
2.0 195 0.400 40
2-1/2 209
0.500
30
3.0 212 26

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR800XD and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR800XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance Plasma HPR800XD
CategoryCutter
LanguageEnglish

Related product manuals