EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
261
Part 2 Programs
Chapter 6 Pseudo-Ladder Task
With the SSEL Controller, a pseudo-ladder task function can be used depending on the command and
extension condition.
The input format is shown below. Note that this function must be used by expert engineers with a full
knowledge of PLC software design.
1. Basic Frame
Extension condition N Input condition Command Operand 1 Operand 2 Output
E Cnd Cmnd Pst
LD 7001 CHPR 1
TPCD 1
TAG 1
l l l l
l l l l
l l l l
l l l l
l l l l
l
l l l
LD 7001 TSLP 1 ~ 100
l l l l
l l l l
l l l l
l l l l
l l l l
l
l l l
LD 7001 TSLP 1 ~ 100
LD 7001 GOTO 1
LD
7001 EXIT
* * Virtual input 7001: “Normally ON” contact
Ladder
statement
field
Ladder
statement
field

Table of Contents