EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
246
Part 2 Programs
1.25 Extended Command
ECMD1 (Get motor current value (as percentage of rated current))
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional ECMD 1
Axis
number
CC
[Function] Store the motor current value (percentage of the rated current) corresponding to the “axis
number” specified in operand 2, in variable 99.
Note: The current value data (percentage of the rated current) obtained by this command has been
processed by feedback current filtering and includes analog error.
[Example] ECMD 1 2 Extended command 1
Store the motor current value (percentage of the rated
current) of axis 2, in variable 99.

Table of Contents

Other manuals for IAI ssel

Related product manuals