34
Part 1 Installation
7. Wiring
7.1 Connecting the Power Cables
As shown to the left, insert the stripped end of each cable
into the connector, and tighten the screws with a
screwdriver.
Recommended cable diameter
Motor power (L1, L2): 2 mm (AWG14)
Control power (L1C, L2C): 0.75 mm (AWG18)
Recommended stripped-wire length: 7 mm
As shown to the left, tighten the screws to affix the
connector.
Note) Always install a noise filter.
Recommended noise filter
Controller power supply Manufacture and model name
100 VAC TDK Lambda MC1210
200 VAC TDK Lambda MC1210