Table 4. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 8431 Frame ID error 1. Check cabling
2. Set the I/O type to 85. See
Power Control Network Utilities
Menu on page 389.
3. Primary I/O backplane
Location: U0.1-P1
1011 8441 Internal SPCN error in a drawer
1. Check the internal SPCN
cables in the CEC drawer
Location: U1.1
2. Check the internal SPCN
cables in the I/O drawer
Location: U0.x
10118450 I/O type set incorrectly Set the I/O type to 85. See Power
Control Network Utilities Menu on
page 389.
1011 8A00 A different I/O drawer is connected to the
CEC
Informational only
1011 9014 Invalid address mode Update system firmware
1011 9038 Node fault Primary I/O backplane
Location: U0.1-P1
1011 9039 Node fault Primary I/O backplane
Location: U0.1-P1
1011 9042 EPROM failure Primary I/O backplane
Location: U0.1-P1
1011 9043 Download failure
1. Check for system firmware
update.
2. Call service support.
1011 9046 QDS packet sequence error
1. Check for system firmware
update.
2. Call service support.
1011 9047 QDS block sequence error
1. Check for system firmware
update.
2. Call service support.
1011 9080 Undefined status code received Primary I/O backplane
Location: U0.1-P1
1011 90F0 CEC backplane not present in
configuration table
Check cabling
1011 9101 SPCN failed to respond to service
processor in time
Primary I/O backplane
Location: U0.1-P1
1011 9102 Permanent address assignment failed Primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
181