Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80070208-0a01xxxx
80070208-0a02xxxx
Sensor PS n Therm
Fault has
transitioned to
critical from a less
severe state. (n =
power supply
number)
Error A sensor has
changed to Critical
state from a less
severe state.
1. Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2. Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www-
03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
3. Replace power supply n.
(n = power supply number)
80070603-0701xxxx Sensor Pwr Rail 1
Fault has
transitioned to
non-recoverable
Error A sensor has
changed to
Nonrecoverable
state.
See more information in “Power
problems” on page 289 and “Solving
power problems” on page 296.
80070603-0701xxxx Sensor Pwr Rail 2
Fault has
transitioned to
non-recoverable
Error A sensor has
changed to
Nonrecoverable
state.
See more information in “Power
problems” on page 289 and “Solving
power problems” on page 296.
80070603-0701xxxx Sensor Pwr Rail 3
Fault has
transitioned to
non-recoverable
Error A sensor has
changed to
Nonrecoverable
state.
See more information in “Power
problems” on page 289 and “Solving
power problems” on page 296.
80070603-0701xxxx Sensor Pwr Rail 4
Fault has
transitioned to
non-recoverable
Error A sensor has
changed to
Nonrecoverable
state.
See more information in “Power
problems” on page 289 and “Solving
power problems” on page 296.
80070603-0701xxxx Sensor Pwr Rail 5
Fault has
transitioned to
non-recoverable
Error A sensor has
changed to
Nonrecoverable
state.
See more information in “Power
problems” on page 289 and “Solving
power problems” on page 296.
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS n 12V
AUX Fault has
transitioned to
non-recoverable from
a less severe state. (n
= power supply
number)
Error A sensor has
changed to
non-recoverable
state from a less
severe state.
1. Check power supply n LED.
2. Replace power supply n.
(n = power supply number)
180 System x3300 M4 Type 7382: Installation and Service Guide