Sense Key 6 (Unit Attention)
Table 37: ASC, and ASCQ summary for Sense Key 6 (Unit Attention)
ASC ASCQ Description
00 02 End-of-partition/medium detected, early warning
28 00 Not ready to ready transition, medium might have changed
29 00 Power-on, reset, or bus device reset occurred
2A 01 Mode parameters changed
2A 02 Log parameters changed
2F 00 Commands cleared by another initiator
30 00 Incompatible medium Installed
3F 01 Microcode has been changed
3F 02 Changed operating denition
3F 03 Inquiry data has changed
5A 01 Operator medium removal request
82 83 Cleaning completed, cleaning cartridge ejected
EE xx Encryption related
EE 12 Encryption - key change detected
EE 18 Encryption - changed (read)
EE 19 Encryption - changed (write)
EE 40 Encryption - Encryption Key Manager identier changed
EE 41 Encryption - Encryption Key Manager challenge changed
EE 50 Encryption - initiator identier changed
EE 51 Encryption - initiator response changed
EF xx Encryption related
Sense Key 7 (Data Protect)
Table 38: ASC, and ASCQ summary for Sense Key 7 (Data Protect)
ASC ASCQ Description
27 00 Write protected
50 01 Data protect, write append position error
EE xx Encryption related
EF xx Encryption related
EF 10 Encryption - key required
EF 11 Encryption - key generation
EF 13 Encryption - key translate
EF 1A Encryption - key optional
52 IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information