4 Using the Data
17-14 WindO/I-NV4 User’s Manual
4.2 Notifying with a Beep when the Counted Operation Time Reaches the Threshold
1 On the Configuration tab, in the System Setup group, click Preventive Maintenance.
The Preventive Maintenance Settings dialog box is displayed.
2 Specify the number of device addresses to monitor in Number of Items.
3 Select the number to register the Preventive Maintenance settings to in Settings, then click Edit.
The Individual Settings dialog box is displayed.
4 Specify the bit device or the bit number of the word device to monitor with Monitor Device Address.
5 Select the Measure Operation Time check box on the Operation Time tab and specify the destination device
address for the counted operation time.
6 Select the data type for the value of Measure Operation Time device address with Data Type.