2.4 Clock function
The boiler is equipped with a digital clock and offers the possibility to program 4
points in time to switch from CH off or CH on.
During the “clock active” periods the boiler will respond on CH demands from the
room thermostat. During the “clock inactive” periods the boiler will not respond on
CH demands.
Additionally the following special modes can be chosen:
A. t-on (temporary on).
The boiler will respond to every CH demand from the room thermostat until
the next switch moment.
B. c-on (continuous on).
The boiler will respond to every CH demand from the room thermostat
without any time limit.
C. OFF.
The boiler will not respond to any CH demand from the room thermostat.
Note
For setting and adjusting the clock see § 9.3 Setting and adjusting the clock
functions
2.5 PC Interface
The burner manager is equipped with an interface for a PC, which can be
connected by means of a special cable and associated software. This facility
allows the behaviour of the burner manager , the appliance and the heating
installation to be monitored over a longer period.
2.6 Test program’s
The burner manager has a facility for placing the appliance in test mode.
Activation of a test program will result in the appliance starting operation
at a fixed fan speed, without the control functions being actuated.
The safety functions do remain active.
The test program is ended by pressing the and simultaneously.
Test programs
Program description
Button
combinations
Display reading
Burner on at minimum CH power
and
“L”
Burner on with maximum CH power
setting (See section 8.3, parameter 3)
and (1x) “h”
Burner on with maximum DHW power
(See section 8.3, parameter 4)
and (2x) "H"
Switch off test program and
Standard
situation
Additional readings :
During test mode the following data can be read :
By pressing the button continuously in the display the CH water pressure is
shown.
By pressing the button continuously in the display the ionisation current is
shown.

Table of Contents

Other manuals for Intergas Rapid 25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intergas Rapid 25 and is the answer not in the manual?

Intergas Rapid 25 Specifications

General IconGeneral
Boiler TypeCombi
DHW Output25 kW
Efficiency Rating93%
Flow Rate10.2 l/min
MountingWall Mounted
ERP EfficiencyA
Max Gas Rate2.78 m³/h
Dimensions (H x W x D)590 x 450 x 240 mm

Related product manuals