5.2 Boiler location
The appliance can be fitted to a mounting frame. The assembly or just the
appliance should be mounted to a wall with sufficient bearing strength. In
case of light wall constructions, resonance sounds may occur.
There must be an earthed electrical supply within a distance of 1 m from
the appliance.
In order to avoid freezing of the condensate discharge, the appliance
should be installed in a frost-free room.
Keep 5 cm free space above the appliance in order to be able to remove
the front panel from the casing.
5.2.1 Installation in a kitchen cupboard
Make sure there is sufficient ventilation above and below the appliance.
When the appliance is placed in a small cupboard, ventilation openings of
at least 50 cm
2
must be made.
5.2.2 Installation in an airing cupboard
Compartment ventilation is not required for a standard airing cupboard (eg
0.6 x 0.6 x 2.3m high).
5.2.3 Remove front panel
Remove the optional pipework cover and the front panel for carrying out
work on the appliance as follows:-
1. Remove the pipework cover (A), if used, forwards.
2. Unscrew both screws (B) at the bottom of the appliance.
3. Lift the front panel (C) and remove it forwards.

Table of Contents

Other manuals for Intergas Rapid 25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intergas Rapid 25 and is the answer not in the manual?

Intergas Rapid 25 Specifications

General IconGeneral
Boiler TypeCombi
DHW Output25 kW
Efficiency Rating93%
Flow Rate10.2 l/min
MountingWall Mounted
ERP EfficiencyA
Max Gas Rate2.78 m³/h
Dimensions (H x W x D)590 x 450 x 240 mm

Related product manuals